Ignore:
Timestamp:
Jun 5, 2026, 1:30:00 PM (5 days ago)
Author:
f.jahn
Message:

vor cube code generierung

File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/fw_g473rct/SES/src/ltc_current.c

    r63 r71  
    4545
    4646
    47   //Umrechnung in °C mit LM61 Sensor
     47  #if DEVICETYPE == 125
    4848  temp1 = temp1 * 600; //6 / 20 / 0.0005;
    4949  temp2 = temp2 * 600; //6 / 20 / 0.0005;
     50  #elif DEVICETYPE == 250
     51  temp1 = temp1 /  20;
     52  temp1 = temp1 * 6;
     53  temp1 = temp1 / 0.000250;
     54  temp2 = temp2 /  20;
     55  temp2 = temp2 * 6;
     56  temp2 = temp2 / 0.000250;
     57  #endif
    5058
    51   //2Nackommastellen
    52   //milli grad in grad * 100 /festkomma
    53   sys_data.s.values.ltc_discharge_current = temp1;
    54   sys_data.s.values.ltc_charge_current = temp2;
     59
     60  //Nur Amperere
     61  //
     62  sys_data.s.values.ltc_discharge_current = temp1/1000;
     63  sys_data.s.values.ltc_charge_current = temp2/1000;
    5564
    5665