Ignore:
Timestamp:
Feb 19, 2026, 12:13:03 PM (9 days ago)
Author:
f.jahn
Message:
 
Location:
Einschaltstrombegrenzung_v2/production
Files:
5 edited

Legend:

Unmodified
Added
Removed
  • Einschaltstrombegrenzung_v2/production/bom.csv

    r26 r27  
    22C1,CP_Elec_8x10.5,1,100µF,
    33D1,D_MiniMELF,1,BZV55B15,
    4 D2,DIODE_SMBJ,1,SMBJ30A,
     4D2,D_SMB,1,SMBJ30A,
    55D3,SODFL2512X73N,1,SS16M,
    66"FID1, FID2, FID3",Fiducial_1mm_Mask3mm,3,Fiducial,
    7 J2,"MKDS 5  3-7,62",1,Conn_01x03,
    8 Q1,PowerPAK_SO-8_Single,1,TPH3R10AQM,
     7J2,7.62_wüth_tbl,1,Conn_01x03,
     8"Q1, Q2, Q3",PowerPAK_SO-8_Single,3,TPH3R10AQM,
    99"R1, R2",0805,2,22k,
  • Einschaltstrombegrenzung_v2/production/designators.csv

    r25 r27  
    1616J2:1
    1717Q1:1
     18Q2:1
     19Q3:1
    1820R1:1
    1921R2:1
  • Einschaltstrombegrenzung_v2/production/netlist.ipc

    r26 r27  
    22P  UNITS CUST 0
    33P  arrayDim   N
    4 317NET-(D1-K)       VIA        MD0157PA00X+058681Y-029921X0315Y0000R000S3
    5 317NET-(D1-K)       VIA        MD0157PA00X+057937Y-022933X0315Y0000R000S3
    6 317+24V             VIA        MD0157PA00X+059311Y-029921X0315Y0000R000S3
    7 317GND1             VIA        MD0157PA00X+052559Y-021850X0315Y0000R000S3
    8 317GND1             VIA        MD0157PA00X+054134Y-021850X0315Y0000R000S3
    9 317GND1             VIA        MD0157PA00X+052953Y-026969X0315Y0000R000S3
    10 317GND1             VIA        MD0157PA00X+052165Y-025394X0315Y0000R000S3
    11 317GND1             VIA        MD0157PA00X+052559Y-025787X0315Y0000R000S3
    12 317GND1             VIA        MD0157PA00X+052559Y-026575X0315Y0000R000S3
    13 317GND1             VIA        MD0157PA00X+053740Y-022224X0315Y0000R000S3
    14 317GND1             VIA        MD0157PA00X+053740Y-026929X0315Y0000R000S3
    15 317GND1             VIA        MD0157PA00X+054528Y-026969X0315Y0000R000S3
    16 317GND1             VIA        MD0157PA00X+052165Y-026181X0315Y0000R000S3
    17 317GND1             VIA        MD0157PA00X+052146Y-023031X0315Y0000R000S3
    18 317GND1             VIA        MD0157PA00X+054134Y-026555X0315Y0000R000S3
    19 317GND1             VIA        MD0157PA00X+052953Y-022205X0315Y0000R000S3
    20 317GND1             VIA        MD0157PA00X+052165Y-022244X0315Y0000R000S3
    21 317GND1             VIA        MD0157PA00X+053346Y-026594X0315Y0000R000S3
    22 317GND1             VIA        MD0157PA00X+052559Y-024213X0315Y0000R000S3
    23 317GND1             VIA        MD0157PA00X+052165Y-026969X0315Y0000R000S3
    24 317GND1             VIA        MD0157PA00X+052559Y-022638X0315Y0000R000S3
    25 317GND1             VIA        MD0157PA00X+052165Y-024606X0315Y0000R000S3
    26 317GND1             VIA        MD0157PA00X+052165Y-023799X0315Y0000R000S3
    27 317GND1             VIA        MD0157PA00X+052559Y-025000X0315Y0000R000S3
    28 317GND1             VIA        MD0157PA00X+053346Y-021850X0315Y0000R000S3
    29 317GND1             VIA        MD0157PA00X+052559Y-023425X0315Y0000R000S3
    30 327+24V             R1    -1          A01X+059414Y-031496X0404Y0551R180S2
    31 327NET-(D1-K)       R1    -2          A01X+058696Y-031496X0404Y0551R180S2
    32 367N/C              H3          D0394UA00X+061024Y-022047X0394Y0000R270S0
    33 367N/C              H1          D0394UA00X+051181Y-031496X0394Y0000R000S0
     4317NET-(D1-K)       VIA        MD0157PA00X+055610Y-031496X0315Y0000R000S1291355155
     5317NET-(D1-K)       VIA        MD0157PA00X+056398Y-022872X0315Y0000R000S1291355155
     6317NET-(D1-K)       VIA        MD0157PA00X+056398Y-019882X0315Y0000R000S1291355155
     7317NET-(D1-K)       VIA        MD0157PA00X+056299Y-027461X0315Y0000R000S1291355155
     8317NET-(D1-K)       VIA        MD0157PA00X+056004Y-034350X0315Y0000R000S1291355155
     9317NET-(D1-K)       VIA        MD0157PA00X+056398Y-016929X0315Y0000R000S1291355155
     10317+24V             VIA        MD0157PA00X+055325Y-026870X0315Y0000R000S1291355155
     11317GND1             VIA        MD0157PA00X+052559Y-021850X0315Y0000R000S1291355155
     12317GND1             VIA        MD0157PA00X+052559Y-017224X0315Y0000R000S1291355155
     13317GND1             VIA        MD0157PA00X+052165Y-025394X0315Y0000R000S1291355155
     14317GND1             VIA        MD0157PA00X+052559Y-025787X0315Y0000R000S1291355155
     15317GND1             VIA        MD0157PA00X+052559Y-026575X0315Y0000R000S1291355155
     16317GND1             VIA        MD0157PA00X+052165Y-019193X0315Y0000R000S1291355155
     17317GND1             VIA        MD0157PA00X+052559Y-019587X0315Y0000R000S1291355155
     18317GND1             VIA        MD0157PA00X+052165Y-026181X0315Y0000R000S1291355155
     19317GND1             VIA        MD0157PA00X+052165Y-016831X0315Y0000R000S1291355155
     20317GND1             VIA        MD0157PA00X+052165Y-020768X0315Y0000R000S1291355155
     21317GND1             VIA        MD0157PA00X+052165Y-021555X0315Y0000R000S1291355155
     22317GND1             VIA        MD0157PA00X+052146Y-023031X0315Y0000R000S1291355155
     23317GND1             VIA        MD0157PA00X+052559Y-020374X0315Y0000R000S1291355155
     24317GND1             VIA        MD0157PA00X+052165Y-019980X0315Y0000R000S1291355155
     25317GND1             VIA        MD0157PA00X+052559Y-016437X0315Y0000R000S1291355155
     26317GND1             VIA        MD0157PA00X+052165Y-018386X0315Y0000R000S1291355155
     27317GND1             VIA        MD0157PA00X+052165Y-022244X0315Y0000R000S1291355155
     28317GND1             VIA        MD0157PA00X+052559Y-018012X0315Y0000R000S1291355155
     29317GND1             VIA        MD0157PA00X+052559Y-024213X0315Y0000R000S1291355155
     30317GND1             VIA        MD0157PA00X+052146Y-017618X0315Y0000R000S1291355155
     31317GND1             VIA        MD0157PA00X+052165Y-026969X0315Y0000R000S1291355155
     32317GND1             VIA        MD0157PA00X+052559Y-021161X0315Y0000R000S1291355155
     33317GND1             VIA        MD0157PA00X+052559Y-022638X0315Y0000R000S1291355155
     34317GND1             VIA        MD0157PA00X+052165Y-024606X0315Y0000R000S1291355155
     35317GND1             VIA        MD0157PA00X+052165Y-023799X0315Y0000R000S1291355155
     36317GND1             VIA        MD0157PA00X+052559Y-018799X0315Y0000R000S1291355155
     37317GND1             VIA        MD0157PA00X+052559Y-025000X0315Y0000R000S1291355155
     38317GND1             VIA        MD0157PA00X+052559Y-023425X0315Y0000R000S1291355155
     39327+24V             R1    -1          A01X+057446Y-028346X0404Y0551R180S2
     40327NET-(D1-K)       R1    -2          A01X+056727Y-028346X0404Y0551R180S2
     41367N/C              H3          D0394UA00X+068898Y-012795X0394Y0000R270S0
     42367N/C              H1          D0394UA00X+042323Y-034449X0394Y0000R000S0
    3443327N/C              FID2              A01X+061024Y-033465X0394Y0000R000S2
    35 327+24V             D3    -1          A01X+059317Y-030512X0705Y0386R180S2
    36 327NET-(D1-K)       D3    -2          A01X+058656Y-030512X0429Y0346R180S2
     44327+24V             D3    -1          A01X+057348Y-027461X0705Y0386R180S2
     45327NET-(D1-K)       D3    -2          A01X+056687Y-027461X0429Y0346R180S2
    3746367N/C              H6          D1260UA00X+070866Y-009843X1260Y0000R000S0
    38 367N/C              H2          D0394UA00X+061024Y-031496X0394Y0000R000S0
    39 327NET-(D1-K)       C1    -1          A01X+056575Y-031496X1732Y0984R180S2
    40 327GND              C1    -2          A01X+053661Y-031496X1732Y0984R180S2
     47367N/C              H2          D0394UA00X+068898Y-034449X0394Y0000R000S0
     48327NET-(D1-K)       C1    -1          A01X+056614Y-031496X1732Y0984R000S2
     49327GND              C1    -2          A01X+059528Y-031496X1732Y0984R000S2
    4150367N/C              H8          D1260UA00X+040945Y-037795X1260Y0000R000S0
    42 327NET-(D1-K)       D1    -1          A01X+057283Y-022933X0512Y0669R090S2
    43 327GND              D1    -2          A01X+057283Y-024311X0512Y0669R090S2
     51327NET-(D1-K)       D1    -1          A01X+056398Y-034350X0512Y0669R000S2
     52327GND              D1    -2          A01X+057776Y-034350X0512Y0669R000S2
    4453327N/C              FID1              A01X+051181Y-033465X0394Y0000R000S2
    4554367N/C              H7          D1260UA00X+070866Y-037795X1260Y0000R000S0
    46 367N/C              H4          D0394UA00X+051181Y-022047X0394Y0000R090S0
     55367N/C              H4          D0394UA00X+042323Y-012894X0394Y0000R090S0
    4756327GND              Q1    -1          A01X+056047Y-024372X0500Y0240R180S2
    4857327GND              Q1    -2          A01X+056047Y-023872X0500Y0240R180S2
     
    5463327GND1             Q1    -5          A01X+053896Y-023372X0402Y0240R180S2
    5564327GND1             Q1    -5          A01X+053896Y-022872X0402Y0240R180S2
    56 327NET-(D1-K)       R2    -1          A01X+055473Y-033858X0404Y0551R180S2
    57 327GND              R2    -2          A01X+054755Y-033858X0404Y0551R180S2
     65327NET-(D1-K)       R2    -1          A01X+056727Y-029232X0404Y0551R000S2
     66327GND              R2    -2          A01X+057446Y-029232X0404Y0551R000S2
    5867367N/C              H5          D1260UA00X+040945Y-009843X1260Y0000R000S0
    59 327GND              D2    -A          A01X+055921Y-025591X0701Y0850R180S2
    60 327GND1             D2    -C          A01X+054319Y-025591X0701Y0850R000S2
    61 327N/C              FID3              A01X+051181Y-015748X0394Y0000R000S2
    62 317+24V             J2    -1    D0512PA00X+058906Y-019685X1181Y0000R180S0
    63 317GND              J2    -2    D0512PA00X+055906Y-019685X1181Y0000R180S0
    64 317GND1             J2    -3    D0512PA00X+052906Y-019685X1181Y0000R180S0
     68327GND              Q2    -1          A01X+056071Y-021419X0500Y0240R180S2
     69327GND              Q2    -2          A01X+056071Y-020919X0500Y0240R180S2
     70327GND              Q2    -3          A01X+056071Y-020419X0500Y0240R180S2
     71327NET-(D1-K)       Q2    -4          A01X+056071Y-019919X0500Y0240R180S2
     72327GND1             Q2    -5          A01X+054748Y-020669X1500Y1539R180S2
     73327GND1             Q2    -5          A01X+053919Y-021419X0402Y0240R180S2
     74327GND1             Q2    -5          A01X+053919Y-020919X0402Y0240R180S2
     75327GND1             Q2    -5          A01X+053919Y-020419X0402Y0240R180S2
     76327GND1             Q2    -5          A01X+053919Y-019919X0402Y0240R180S2
     77327GND              Q3    -1          A01X+056071Y-018467X0500Y0240R180S2
     78327GND              Q3    -2          A01X+056071Y-017967X0500Y0240R180S2
     79327GND              Q3    -3          A01X+056071Y-017467X0500Y0240R180S2
     80327NET-(D1-K)       Q3    -4          A01X+056071Y-016967X0500Y0240R180S2
     81327GND1             Q3    -5          A01X+054748Y-017717X1500Y1539R180S2
     82327GND1             Q3    -5          A01X+053919Y-018467X0402Y0240R180S2
     83327GND1             Q3    -5          A01X+053919Y-017967X0402Y0240R180S2
     84327GND1             Q3    -5          A01X+053919Y-017467X0402Y0240R180S2
     85327GND1             Q3    -5          A01X+053919Y-016967X0402Y0240R180S2
     86327GND1             D2    -1          A01X+054665Y-025787X0984Y0906R000S2
     87327GND              D2    -2          A01X+056358Y-025787X0984Y0906R000S2
     88327N/C              FID3              A01X+051181Y-009941X0394Y0000R000S2
     89317+24V             J2    -1    D0512PA00X+058906Y-013780X1181Y0000R180S0
     90317GND              J2    -2    D0512PA00X+055906Y-013780X1181Y0000R180S0
     91317GND1             J2    -3    D0512PA00X+052906Y-013780X1181Y0000R180S0
    6592999
  • Einschaltstrombegrenzung_v2/production/positions.csv

    r25 r27  
    11Designator,Mid X,Mid Y,Rotation,Layer
    2 C1,140.0,-80.0,0.0,top
    3 D1,145.5,-60.0,270.0,top
    4 D2,140.005,-65.0,0.0,top
    5 D3,150.0,-77.5,180.0,top
     2C1,147.5,-80.0,180.0,top
     3D1,145.0,-87.25,0.0,top
     4D2,141.0,-65.5,0.0,top
     5D3,145.0,-69.75,180.0,top
    66FID1,130.0,-85.0,0.0,top
    77FID2,155.0,-85.0,0.0,top
    8 FID3,130.0,-40.0,0.0,top
    9 H1,130.0,-80.0,0.0,top
    10 H2,155.0,-80.0,0.0,top
    11 H3,155.0,-56.0,90.0,top
    12 H4,130.0,-56.0,270.0,top
    13 J2,142.0,-50.0,180.0,top
     8FID3,130.0,-25.25,0.0,top
     9H1,107.5,-87.5,0.0,top
     10H2,175.0,-87.5,0.0,top
     11H3,175.0,-32.5,90.0,top
     12H4,107.5,-32.75,270.0,top
     13J2,142.0,-35.0,180.0,top
    1414Q1,139.69,-60.0,90.0,top
    15 R1,150.0,-80.0,180.0,top
    16 R2,139.99,-86.0,180.0,top
     15Q2,139.75,-52.5,90.0,top
     16Q3,139.75,-45.0,90.0,top
     17R1,145.0,-72.0,180.0,top
     18R2,145.0,-74.25,0.0,top